Product

>
<

10W charger

TPA166A-10050-CH


Appearance color: black, red

Pin type: wall-mounted horizontal, medium gauge

Output power: 10W

Input voltage: 90~264V

Input frequency: 47~63Hz

Output voltage: 5V

Output voltage accuracy: 5%

Output current: 2.0A

Mean time between failures: at least 50,000 hours

Protection: overcurrent and overvoltage

Efficiency: 73.4%

Inrush current: cold start 30A/220VAC

Working temperature: -5~+40°C

Safety certification: CCC

Packing: 0.09kg/100pcs/10kg

Warranty period: 2 years


Product Detail

General

The specification defines the performance characteristics of a 12 W, SINGLE Output level switching power supply for IT. The power supply has designed highly reliable and meet international safety and radiation requirements.


1.0 Input Characteristics

1.1Input voltage range and frequency

Nominal Voltages

Voltage Variation Range

Nominal Frequency

Frequency Variation Range

  100-240VAC

90-264VAC

50-60Hz

47-63Hz

Rated voltage: 100-240VAC

Voltage variation range: 90-264VAC

Rated frequency: 50-60Hz

Frequency change range: 47-63Hz

1.2 Input Current

0. 35A max

 At AC low line input and DC output full load

At low line AC and full load, the maximum input current is 0.35A

1.3 Input protection


5A Fuse

 The power supply shall be protected against power line surges and any abnormal condition.


When the AC input voltage has surges and abnormal conditions, the 5A fuse will protect the power supply

1.4 Input surge current

30A  max

 At power supply cold start, ambient temperature 25℃230Vac



When the input is 230Vac cold state at 25℃ ambient temperature, the maximum surge current is 30A

1.5 Efficiency

1.5.1 %min. At nominal input voltage,maximum load and measured at end of DC cable

In the case of rated input voltage and full load, the efficiency of the DC line end is% minimum

1.5.2 Active mode efficiency:

More than 72.4% min of average efficiency of 25%,50%,75% and 100% load tested at 230Vac.(Warm up after 30 minutes)

At 230Vac input, the average efficiency under 25%, 50%, 75%, and 100% load conditions is at least 72.4%

(Record data after 30 minutes of aging)

1.6 No Load Power consumption


0.5W rms max

 At AC nominal inputoutput no load


In the case of rated input AC and output no-load, the maximum no-load loss is 0.5W

1.7 Hold up time


5ms min

 At 115VAC nominal inputoutput full load


(1 half cycle)


In the case of rated input 115VAC and output full load, the minimum holding time is 5ms.

2.0 Output Characteristics

2.1 Turn on delay


 2S max

 At 115VAC low line inputoutput full load


In the case of 115VAC low-voltage input and output with full load, the boot delay time is up to 2S

*Test on delay is measured from 0 voltage output to the main output regulation.

2.2 DC output regulation


Voltage(V)

Loading(A)

Tolerance Range

Total Regulation

Adjustable voltage

Range(V)


Min

Max




+5.0

0

2.4

±5%

None

4.75-5.25


*Total regulation involved line regulation load regulation cross regulation---etc.

*Line regulation is measured from 90Vac to 132Vac or 185vac to 264vac

*Load regulation is measured all output from min load to max load at 115vac

or 230vac nominal AC input voltage

*The total adjustment rate relates to the cross adjustment rate of linearity and load

*The test condition of linear adjustment rate is 90Vac to 132Vac or 185Vac to 264Vac

*The test condition of load regulation is the change from the minimum load to the maximum load under the input of 115Vac/230Vac.

2.3 Ripple/noise

Voltage(V)

Ripple/Noise(pk-pk)(mV)

+5.0

120

*The ripple is measured from peak to peak with band width limit of 20MHz

(By passed at the end of connector with 10uF electrolytic and 0.1uF ceramic disk capacitor under DC output full Load, 90-264Vac input 25℃ambient temperature).

*Ripple is obtained by measuring the peak-to-peak value using the oscilloscope bandwidth of 20MHz.

(Test conditions: at full DC output, 90-264Vac input, and 25°C ambient temperature, a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor are connected in parallel at the output)

3.0 Protection

3.1 Short protection / Over current protection

The power supply will self-protect any output to ground, And auto recovery when

abnormal circuit faults remove.

The power supply can automatically resume normal operation when the short circuit is removed

*An output short circuit is defined as any output impedance of less than 0.1 ohms.

*When the effective value of output impedance is less than 0.1 ohm, it is defined as output short circuit

Voltage(V)

OCP Current(A)

Power in(W)

OCP method




latch off

Current limit

Fold back

+5.0

 2.8A





3.2 Over voltage protection

Voltage(V)

OVP range

OVP Method



Latch off

Auto recovery

Voltage limit

+5.0





Test methods: Short FB Pin to GND

3.3 Over Temperature Protection

No deformation and no discoloration on case and will be shut down. That will be return

To normal state by ac reset, reset≤2 minutes.

When the power supply is turned off, the shell is not damaged or stained. When the AC input is restored, the shell can be restored to a normal state, and the recovery time is less than 2 minutes.

4.0 Leakage current:

Leakage current 0.25 mA max@240VAC

When the input voltage is 240Vac, the maximum leakage current is 0.25mA

5.0 Safety meet of GB8898-2011

5.1 EMI/EMS standards EMI/EMS STANDARDS

5.1.1 EMI EN55013 EMS EN55020

5.1.2 EN61000-4-2 ESD immunity requirements

5.1.2.1 Air discharge +/- 8KV (B)

5.1.2.2 Contact discharge +/- 6KV (B)

5.2 EN61000-4-3 radiated disturbance field strength RS

3V/m (r.m.s) 80-1000Mz 80%AM (1KHz) sine-wave (A)

5.3 EN61000-4-4 Electrical Fast Transient Burst BURST

5.3.1 AC input port AC-input coupling 0.5KV (A)

5.3.2 AC input port AC-input coupling 1KV (B)

5.4 EN61000-4-5 Surge immunity test SCR

5.4.1 Common mode/differential mode +/- 2KV / +/- 1KV

5.5 Induced radio frequency fields conducted disturbances immunity test

3V 0.15-80 MHz 80%AM (1KHz) (A)

6.0 HI-POT

HI-POT---A IEC 320 3pin primary to secondary (FG) 1500Vac 5mA 3S

HI-POT---B IEC 320 2pin primary to secondary 3000Vac 5mA 60S

When 3Pin input, primary to secondary, 1500VAC/5mA/3S.

When 2Pin input, primary to secondary, 3000Vac/5mA/60S.


7.0 Environment

TEMPERATURE AND HUMIDITY

OPERATING TEMPERATURE 0 DEGREES C TO 40 DEGREES C.

OPERATING HUMIDITY 5% TO 90% RH.(RELATIVE HUMIDITY).

STORAGE TEMPERATURE -20 DEGREES C TO 85 DEGREES C.

STORAGE HUMIDITY 5% TO 90% RH. (RELATIVE HUMIDITY).

Working temperature: 0℃-40℃

Working humidity: 5%-90% (relative humidity)

Storage temperature: -20℃-85℃

Storage humidity: 5%-90% (relative humidity)


8.0 Vibration

SWEEP AND RESONANCE SEARCH

FREQUENCY DURATION AXIS AMPLITUDE

10~55Hz 30 MINUTES X,Y,Z 1G


9.0 M.T.B.F

Shall be 50000 power on hours on greater under 25 degrees C of ambient temperature MTBF

Under evaluated under.

*M.T.B.F 50000 hours will be affected if the product won’t be used for a long time.

10 Label specification: As Attachment

11 Mechanical: As Attachment

12 Appearance: As Attachment

13 Package: As Attachment

14 SCH&PCB: As Attachment

15 Bill of materiel: As Attachment

16 Safety certificate: As Attachment